0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
G6D-F4B DC12

G6D-F4B DC12

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

  • 描述:

    通用 继电器 SPST-NO(1 Form A)x 4 12VDC 线圈 DIN 轨道

  • 数据手册
  • 价格&库存
G6D-F4B DC12 数据手册
Terminal Relay G6D-F4B/G3DZ-F4B CSM_G6D-F4B_G3DZ-F4B_DS_E_5_1 Easy-to-use, Space-saving Terminal Relay with Four-point Output • Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) • Each terminal circuit (with coil or contact) is independent from one another. • Short Bar ensures easy connection of common and adjacent terminals. • Provided with a terminal cover that prevents electric-shock accidents. • Relay and MOS FET relay models are available. • LED operation indicator. • Built-in diode absorbs coil surge. • Mounts either on DIN track or screws. • Tool for easy mounting or removal of Relays provided. • UL, CSA, and VDE certification for standard models (VDE: G6D-F4B only). Model Number Structure ■ Model Number Legend G6D/G3DZ-@@ 1 2 1. Terminal Form F: Flat type 2. Number of Relays Mounted 4B: 4 Ordering Information ■ List of Models Output Relay output Contact configuration SPST-NO × 4 Model Rated voltage G6D-F4B 12 VDC G3DZ-F4B 12 VDC 24 VDC Power MOS FET relay output 24 VDC Note: When ordering add the rated coil voltage to the model number. Example: G6D-F4B 24 VDC Rated coil voltage 1 G6D-F4B/G3DZ-F4B Specifications ■ Ratings Coil Ratings (per G6D Relay) Rated voltage Rated current Coil resistance 12 VDC 18.7 mA 720 Ω 24 VDC 10.5 mA 2,880 Ω Must operate voltage 70% max. (see note 1) Must release voltage 10% min. Max. voltage 130% Power consumption Approx. 200 mW Note: 1. 2. 3. 4. The must operate voltage is 75% or less of the rated voltage if the Relay is mounted upside down. Rated current and coil resistance were measured at a coil temperature of 23°C with a tolerance of ±10%. Operating characteristics were measured at a coil temperature of 23°C. The maximum allowable voltage is the maximum value of the allowable voltage range for the relay coil operating power supply. There is no continuous allowance. 5. The rated current includes the terminal’s LED current. Contact Ratings (per G6D Relay) Item Resistive load (cosφ = 1) Rated load 3 A at 250 VAC, 3 A at 30 VDC Rated carry current 5A Max. switching voltage 250 VAC, 30 VDC Max. switching current 5A Max. permissible capacity (reference value) 1,250 VA, 150 W Error rate (reference value) (see note) 5 VDC, 10 mA Note: This value is for a switching frequency of 120 times per minute. ■ Power MOS FET Relay Specifications Input (per G3DZ Power MOS FET Relay) Rated voltage Operating voltage Must operate voltage level 12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 19.2 VDC max. Must release voltage level 1 VDC min. Input impedance Rated current 2 kΩ±20% 8.0 mA±20% 4 kΩ±20% 8.2 mA±20% Note: The rated current includes the terminal’s LED current. Output (per G3DZ Power MOS FET Relay) Load voltage 3 to 264 VAC 3 to 125 VDC Load current 100 µ to 0.3 A Inrush current 6 A (10 ms) Note: There is no output polarity for the G3DZ. 2 G6D-F4B/G3DZ-F4B ■ Characteristics Item G6D-F4B Relay output Contact resistance (see note 2) 100 mΩ max. Must operate time (see note 3) 10 ms max. Release time (see note 3) 10 ms max. Insulation resistance 1,000 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between coil and contacts. 1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity 750 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage (between coil and contacts) 4,000 V (1.2 × 50 µs) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 500 m/s2 Malfunction: 100 m/s2 Endurance Mechanical: 20,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load) 100,000 operations min. (3 A at 30 VDC, resistive load) (at 1,800 operations /hr) Ambient temperature Operating: –25°C to 55°C (with no icing) Ambient humidity Operating: 45% to 85% Weight Approx. 65 g Note: 1. The above values are initial values. 2. Measurement condition: 1 A at 5 VDC 3. Ambient temperature condition: 23°C Item G3DZ-F4B Power MOS FET relay output Must operate time 10 ms max. Release time 15 ms max. Output ON-resistance 2.4 Ω max. Leakage current at OFF state 10 µA max. (at 125 VDC) Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between input and output terminals 1,500 VAC, 50/60 Hz for 1 min between contacts of different polarity Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 500 m/s2 Ambient temperature Operating: –25°C to 55°C (with no icing) Ambient humidity Operating: 45% to 85% Weight Approx. 65 g 3 G6D-F4B/G3DZ-F4B Engineering Data  Maximum Switching Power  Endurance DC resistive load AC resistive load 500 300 Endurance (x104 operations) Switching current (A) G6D-F4B 100 30 10 5 3 0 250 VAC/30 VDC inductive load (cosφ = 0.4, L/R = 7 ms) 1 2 3 4 5 6 7 8 9 10 Switching current (A) Switching voltage (V)  Load Current vs. Ambient Temperature 250 VAC/30 VDC resistive load 50  Inrush Current Resistivity: Non-repetitive Keep the inrush current to half the rated value if it occurs repetitively. Load current (A) Inrush current (A. Peak) G3DZ-F4B Ambient temperature (°C) Energizing time (ms) 4 G6D-F4B/G3DZ-F4B Dimensions Note: All units are in millimeters unless otherwise indicated. G6D-F4B G3DZ-F4B 16, M3 Phillips head screws Mounting Dimensions Two, 4 dia. holes or M3.5 screw holes 8.7 4 3 8 IN 2 7 6 2 1 Terminal Arrangement/ Internal Connections (Top View) 1 5 3 4 Input side 68 max. 4 3 2 1 8 7 6 5 76±0.3 RY1 RY2 RY3 RY4 OUT 1 12 11 10 9 16 15 14 13 2 3 4 Output side 12 11 10 9 16 15 14 13 8.7 31 max. 35 max. 23±0.3 Tool for removing relays. Note1 : Make sure that the polarity of the input terminal is correct. Note2 : There is no output polarity for the G6D-F4B and G3DZ-F4B. ■ Accessories (Order Separately) G6D-4-SB Short Bar Applicable model G6D-F4B Model G6D-4-SB G3DZ-F4B Relay Mounting Products Short Bar Name Model Mounting track Applicable Terminal Relay PFP-100N G6D-F4B PFP-50N G3DZ-F4B Model G6D-4-SB PFP-100N2 End plate PFP-M Spacer PFP-S Replacement Relays Applicable Terminal Relay G6D-F4B Model G6D-1A-ASI Rated voltage 12 VDC 24 VDC G3DZ-F4B G3DZ-2R6PL 12 VDC 24 VDC Note: Error rate (P level) for the G6D-1A-ASI is 5 V at 10 mA and that for the G6D-1A-AP is 5 V at 1 mA. 5 G6D-F4B/G3DZ-F4B Safety Precautions Refer to Safety Precautions for All Relays. Wiring Wiring Be sure to turn OFF the power when wiring the Unit and do not touch the charged terminals of the Unit. Otherwise, an electric shock may result. Pay utmost attention not to make mistakes with the polarity of the input terminals. Do not apply overvoltage to the input terminals. Otherwise, the Unit may malfunction or burn. Coil Voltage Make sure not to impose voltage exceeding the permissible voltage on the coil continuously. Relay Models Do not connect the Unit to loads exceeding the rated switching power (switching voltage or current). Otherwise, faulty insulation, contact weld, or faulty contact of Relays, or damage to Relays may result, or the Relays may malfunction or burn. Do not connect any inductive load in parallel to the coil input as shown in the following example or power supply with a surge voltage. Otherwise, the surge absorption diode will be damaged. Do Not Use the Following Circuit The life of Relays varies with the switching condition. Test the Relays under the actual operating conditions before using the Relays within the permissible switching frequency. The use of deteriorated Relays may result in the faulty insulation of the Relays or cause the Relays to burn. Do not use the Unit in locations with inflammable gas. Otherwise, a fire or explosion due to the heat of the Relays or sparks from the Relays may result when they are switched. SSR Output (Power MOS FET Relay Model) Do not connect the Unit to loads consuming a total current exceeding the rated output current of the Unit. Otherwise, the output element of the Unit may be damaged and a short or open-circuit malfunction may result. If the Unit is connected to a DC inductive load, connect a diode to the Unit to protect the Unit from counter-electromotive voltage, otherwise the counter-electromotive voltage may damage the output element and a short or open-circuit malfunction may result. Inductive load G6D coil Coil surge absorption diode Handling Do not drop, shock, or vibrate the Unit excessively. Otherwise, damage to the Unit may result or the Unit may malfunction. Make sure that all the Relays are properly mounted before use. Screw Tightening Torque Tighten each terminal screw to a torque of 0.78 to 1.18N·m. Tighten each mounting screw to a torque of 0.59 to 0.98 N·m. ■ Correct Use Installation Environment Mounting Do not install the Unit in the following locations. Otherwise, damage to the Unit may result or the Unit may malfunction. When mounting two or more Units, reduce the current and ON duty and provide an appropriate distance between the Units so that the ambient temperature will not exceed 55°C. Relay Replacement Use the Relay Removal Tool provided with the Unit to dismount a Relay. Locations with direct sunlight. Locations with an ambient temperature range not within –25°C to 55°C. Locations with rapid temperature changes resulting in condensation or locations with relative humidity ranges not within 45% to 85%. Locations with corrosive or inflammable gas. Locations with excessive dust, salinity, or metal powder. Be sure to turn OFF the power to the Unit before replacing a Relay. Locations with vibration or shock affecting the Unit. When mounting a Relay, insert the Relay vertically so that the relay terminals will come in contact with the socket contact pins properly. Locations with water, oil, or chemical sprayed on the Unit. Do not mount Relays that are different to one another in voltage. Disassembly, Repair, and Modification Do not disassemble, repair, or modify the Unit. Otherwise, an electric shock may result or the Unit may malfunction. Mounted Relays Relays and SSRs cannot be mounted together. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6
G6D-F4B DC12 价格&库存

很抱歉,暂时无法提供与“G6D-F4B DC12”相匹配的价格&库存,您可以联系我们找货

免费人工找货